Fiber optical shape sensing of flexible instruments for endovascular navigation S Jäckle, T Eixmann, H Schulz-Hildebrandt, G Hüttmann, T Pätz International journal of computer assisted radiology and surgery 14, 2137-2145, 2019 | 95 | 2019 |
Dynamic contrast in scanning microscopic OCT M Münter, M Vom Endt, M Pieper, M Casper, M Ahrens, T Kohlfaerber, ... Optics letters 45 (17), 4766-4769, 2020 | 60 | 2020 |
Label-free in vivo imaging of corneal lymphatic vessels using microscopic optical coherence tomography J Horstmann, H Schulz-Hildebrandt, F Bock, S Siebelmann, E Lankenau, ... Investigative ophthalmology & visual science 58 (13), 5880-5886, 2017 | 41 | 2017 |
Combined oct distance and fbg force sensing cannulation needle for retinal vein cannulation: in vivo animal validation M Ourak, J Smits, L Esteveny, G Borghesan, A Gijbels, L Schoevaerdts, ... International journal of computer assisted radiology and surgery 14, 301-309, 2019 | 34 | 2019 |
Novel endoscope with increased depth of field for imaging human nasal tissue by microscopic optical coherence tomography H Schulz-Hildebrandt, M Pieper, C Stehmar, M Ahrens, C Idel, ... Biomedical optics express 9 (2), 636-647, 2018 | 33 | 2018 |
Microscopic optical coherence tomography (mOCT) at 600 kHz for 4D volumetric imaging and dynamic contrast M Münter, M Pieper, T Kohlfaerber, E Bodenstorfer, M Ahrens, C Winter, ... Biomedical Optics Express 12 (10), 6024-6039, 2021 | 31 | 2021 |
Three-dimensional guidance including shape sensing of a stentgraft system for endovascular aneurysm repair S Jäckle, V García-Vázquez, T Eixmann, F Matysiak, F von Haxthausen, ... International Journal of Computer Assisted Radiology and Surgery 15 (6 …, 2020 | 29 | 2020 |
Development and experimental validation of a combined fbg force and oct distance sensing needle for robot-assisted retinal vein cannulation J Smits, M Ourak, A Gijbels, L Esteveny, G Borghesan, L Schoevaerdts, ... 2018 IEEE international conference on robotics and automation (ICRA), 129-134, 2018 | 29 | 2018 |
High-speed fiber scanning endoscope for volumetric multi-megahertz optical coherence tomography H Schulz-Hildebrandt, T Pfeiffer, T Eixmann, S Lohmann, M Ahrens, ... Optics letters 43 (18), 4386-4389, 2018 | 28 | 2018 |
An intraoral oct probe to enhanced detection of approximal carious lesions and assessment of restorations H Schneider, M Ahrens, M Strumpski, C Rüger, M Häfer, G Hüttmann, ... Journal of clinical medicine 9 (10), 3257, 2020 | 25 | 2020 |
Dynamic microscopic optical coherence tomography to visualize the morphological and functional micro-anatomy of the airways T Kohlfaerber, M Pieper, M Münter, C Holzhausen, M Ahrens, C Idel, ... Biomedical Optics Express 13 (6), 3211-3223, 2022 | 19 | 2022 |
Microanatomy of the tympanic membrane in chronic myringitis obtained with optical coherence tomography E Guder, E Lankenau, F Fleischhauer, H Schulz-Hildebrandt, G Hüttmann, ... European Archives of Oto-Rhino-Laryngology 272, 3217-3223, 2015 | 19 | 2015 |
3D catheter guidance including shape sensing for endovascular navigation S Jäckle, V García-Vázquez, F von Haxthausen, T Eixmann, MM Sieren, ... Medical Imaging 2020: Image-Guided Procedures, Robotic Interventions, and …, 2020 | 17 | 2020 |
Clinical evaluation of an instrument-integrated OCT-based distance sensor for robotic vitreoretinal surgery MG Cereda, S Parrulli, YGM Douven, K Faridpooya, S van Romunde, ... Ophthalmology Science 1 (4), 100085, 2021 | 16 | 2021 |
Optimization-based vessel segmentation pipeline for robust quantification of capillary networks in skin with optical coherence tomography angiography M Casper, H Schulz-Hildebrandt, M Evers, R Birngruber, D Manstein, ... Journal of Biomedical Optics 24 (4), 046005-046005, 2019 | 16 | 2019 |
Coregistered Spectral Optical Coherence Tomography and Two‐Photon Microscopy for Multimodal Near‐Instantaneous Deep‐Tissue Imaging A Rakhymzhan, L Reuter, R Raspe, D Bremer, R Günther, R Leben, ... Cytometry Part A 97 (5), 515-527, 2020 | 14 | 2020 |
OCT verstehen–Teil 1: Physikalische Grundlagen J Horstmann, S Siebelmann, H Schulz-Hildebrandt, I Glasunow, ... Augenheilkunde up2date 6 (04), 289-300, 2016 | 14 | 2016 |
Intravital microscopic optical coherence tomography imaging to assess mucus-mobilizing interventions for muco-obstructive lung disease in mice M Pieper, H Schulz-Hildebrandt, MA Mall, G Hüttmann, P König American Journal of Physiology-Lung Cellular and Molecular Physiology 318 (3 …, 2020 | 13 | 2020 |
An approach for needle based optical coherence elastography measurements S Latus, C Otte, M Schlüter, J Rehra, K Bizon, H Schulz-Hildebrandt, ... Medical Image Computing and Computer-Assisted Intervention− MICCAI 2017 …, 2017 | 12 | 2017 |
Radiation-free thoracic endovascular aneurysm repair with fiberoptic and electromagnetic guidance: a phantom study MM Sieren, S Jäckle, T Eixmann, H Schulz-Hildebrandt, F Matysiak, ... Journal of Vascular and Interventional Radiology 33 (4), 384-391. e7, 2022 | 9 | 2022 |