Follow
Joao Folgado
Joao Folgado
IDMEC, Instituto Superior Tecnico, Universidade de Lisboa
Verified email at tecnico.ulisboa.pt
Title
Cited by
Cited by
Year
Computational hip joint simulator for wear and heat generation
JC Fialho, PR Fernandes, L Eça, J Folgado
Journal of Biomechanics 40 (11), 2358-2366, 2007
1222007
A contact model with ingrowth control for bone remodelling around cementless stems
PR Fernandes, J Folgado, C Jacobs, V Pellegrini
Journal of Biomechanics 35 (2), 167-176, 2002
1222002
A multibody biomechanical model of the upper limb including the shoulder girdle
C Quental, J Folgado, J Ambrósio, J Monteiro
Multibody System Dynamics 28, 83-108, 2012
992012
On the optimal shape of hip implants
RB Ruben, PR Fernandes, J Folgado
Journal of biomechanics 45 (2), 239-246, 2012
972012
In silico mechano-chemical model of bone healing for the regeneration of critical defects: the effect of BMP-2
FO Ribeiro, MJ Gómez-Benito, J Folgado, PR Fernandes, ...
PloS one 10 (6), e0127722, 2015
642015
Influence of femoral stem geometry, material and extent of porous coating on bone ingrowth and atrophy in cementless total hip arthroplasty: an iterative finite element model
J Folgado, PR Fernandes, CR Jacobs, VD Pellegrini Jr
Computer methods in biomechanics and biomedical engineering 12 (2), 135-145, 2009
512009
Critical analysis of musculoskeletal modelling complexity in multibody biomechanical models of the upper limb
C Quental, J Folgado, J Ambrósio, J Monteiro
Computer methods in biomechanics and biomedical engineering 18 (7), 749-759, 2015
492015
Multibody biomechanical models of the upper limb
J Ambrósio, C Quental, B Pilarczyk, J Folgado, J Monteiro
Procedia IUTAM 2, 4-17, 2011
482011
Fully automatic segmentation of femurs with medullary canal definition in high and in low resolution CT scans
DF Almeida, RB Ruben, J Folgado, PR Fernandes, E Audenaert, ...
Medical engineering & physics 38 (12), 1474-1480, 2016
472016
Shape optimization of a cementless hip stem for a minimum of interface stress and displacement
PR Fernandes, J Folgado, RB Ruben
Computer methods in biomechanics and biomedical engineering 7 (1), 51-61, 2004
452004
Three-dimensional shape optimization of hip prostheses using a multicriteria formulation
RB Ruben, J Folgado, PR Fernandes
Structural and Multidisciplinary Optimization 34, 261-275, 2007
442007
Bone remodelling analysis of the humerus after a shoulder arthroplasty
C Quental, J Folgado, PR Fernandes, J Monteiro
Medical engineering & physics 34 (8), 1132-1138, 2012
402012
Bone adaptation impact of stemless shoulder implants: a computational analysis
M Comenda, C Quental, J Folgado, M Sarmento, J Monteiro
Journal of Shoulder and Elbow Surgery 28 (10), 1886-1896, 2019
392019
Structural analysis of the intervertebral discs adjacent to an interbody fusion using multibody dynamics and finite element cosimulation
NMB Monteiro, MPT da Silva, JOMG Folgado, JPL Melancia
Multibody System Dynamics 25, 245-270, 2011
392011
The influence of the pelvic bone on the computational results of the acetabular component of a total hip prosthesis
S Barreto, J Folgado, PR Fernandes, J Monteiro
362010
Computational model of mesenchymal migration in 3D under chemotaxis
FO Ribeiro, MJ Gómez-Benito, J Folgado, PR Fernandes, ...
Computer methods in BiomeChaniCs and BiomediCal engineering 20 (1), 59-74, 2017
332017
A new shoulder model with a biologically inspired glenohumeral joint
C Quental, J Folgado, J Ambrósio, J Monteiro
Medical engineering & physics 38 (9), 969-977, 2016
332016
3-D solid and finite element modeling of biomechanical structures-a software pipeline
N Ribeiro, P Fernandes, D Lopes, J Folgado, P Fernandes
7th EUROMECH solid mechanics conference, 2-17, 2009
322009
A window moving inverse dynamics optimization for biomechanics of motion
C Quental, J Folgado, J Ambrósio
Multibody System Dynamics 38 (2), 157-171, 2016
282016
Stress analysis in a bone fracture fixed with topology-optimised plates
AA Al-Tamimi, C Quental, J Folgado, C Peach, P Bartolo
Biomechanics and modeling in mechanobiology 19, 693-699, 2020
272020
The system can't perform the operation now. Try again later.
Articles 1–20