Follow
Eung Je Woo
Eung Je Woo
Verified email at khu.ac.kr - Homepage
Title
Cited by
Cited by
Year
Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm
O Kwon, EJ Woo, JR Yoon, JK Seo
IEEE Transactions on Biomedical Engineering 49 (2), 160-167, 2002
3722002
Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging
EJ Woo, JK Seo
Physiological measurement 29 (10), R1, 2008
2822008
Reconstruction of conductivity and current density images using only one component of magnetic field measurements
JK Seo, JR Yoon, EJ Woo, O Kwon
IEEE Transactions on Biomedical Engineering 50 (9), 1121-1124, 2003
2632003
A comparison of autologous and allogenic bone marrow-derived mesenchymal stem cell transplantation in canine spinal cord injury
DI Jung, J Ha, BT Kang, JW Kim, FS Quan, JH Lee, EJ Woo, HM Park
Journal of the neurological sciences 285 (1-2), 67-77, 2009
2542009
Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography
SH Oh, BI Lee, EJ Woo, SY Lee, MH Cho, O Kwon, JK Seo
Physics in Medicine and Biology 48 (19), 3101, 2003
2522003
Magnetic resonance electrical impedance tomography (MREIT)
JK Seo, EJ Woo
SIAM review 53 (1), 40-68, 2011
2172011
Finite element modeling of electrode-skin contact impedance in electrical impedance tomography
P Hua, EJ Woo, JG Webster, WJ Tompkins
IEEE Transactions on Biomedical Engineering 40 (4), 335-343, 1993
1691993
Impedance tomography using internal current density distribution measured by nuclear magnetic resonance
EJ Woo, SY Lee, CW Mun
SPIE's 1994 International Symposium on Optics, Imaging, and Instrumentation …, 1994
1681994
Iterative reconstruction methods using regularization and optimal current patterns in electrical impedance tomography
P Hua, EJ Woo, JG Webster, WJ Tompkins
IEEE Transactions on Medical Imaging 10 (4), 621-628, 1991
1591991
J-substitution algorithm in magnetic resonance electrical impedance tomography (MREIT): phantom experiments for static resistivity images
HS Khang, BI Lee, SH Oh, EJ Woo, SY Lee, MH Cho, O Kwon, JR Yoon, ...
IEEE transactions on medical imaging 21 (6), 695-702, 2002
1572002
A robust image reconstruction algorithm and its parallel implementation in electrical impedance tomography
EJ Woo, P Hua, JG Webster, WJ Tompkins
IEEE Transactions on Medical Imaging 12 (2), 137-146, 1993
1551993
Phenol block of peripheral nerve conduction: titrating for optimum effect
DH Sung, TR Han, WH Park, HJ Bang, JM Kim, SH Chung, EJ Woo
Archives of Physical Medicine and Rehabilitation 82 (5), 671-676, 2001
1482001
Frequency-difference electrical impedance tomography (fdEIT): algorithm development and feasibility study
JK Seo, J Lee, SW Kim, H Zribi, EJ Woo
Physiological measurement 29 (8), 929, 2008
1352008
A fully parallel multi-frequency EIT system with flexible electrode configuration: KHU Mark2
TI Oh, H Wi, PJ Yoo, EJ Woo
Physiological measurement 32 (7), 835, 2011
1282011
Multi-frequency EIT system with radially symmetric architecture: KHU Mark1
TI Oh, EJ Woo, D Holder
Physiological measurement 28 (7), S183, 2007
1272007
Nanofiber web textile dry electrodes for long-term biopotential recording
TI Oh, S Yoon, TE Kim, H Wi, KJ Kim, EJ Woo, RJ Sadleir
IEEE, 2012
1242012
Finite element analyses of uniform current density electrodes for radio-frequency cardiac ablation
S Tungjitkusolmun, EJ Woo, H Cao, JZ Tsai, VR Vorperian, JG Webster
IEEE Transactions on Biomedical Engineering 47 (1), 32-40, 2000
1222000
In vivo high-resolution conductivity imaging of the human leg using MREIT: the first human experiment.
HJ Kim, YT Kim, AS Minhas, WC Jeong, EJ Woo, JK Seo, OJ Kwon
IEEE transactions on medical imaging 28 (11), 1681, 2009
1202009
Electrical conductivity images of biological tissue phantoms in MREIT
SH Oh, BI Lee, EJ Woo, SY Lee, TS Kim, O Kwon, JK Seo
Physiological Measurement 26 (2), S279, 2005
1192005
Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1: impedance spectroscopy and time-difference imaging
TI Oh, H Koo, KH Lee, SM Kim, J Lee, SW Kim, JK Seo, EJ Woo
Physiological Measurement 29 (3), 295, 2008
1162008
The system can't perform the operation now. Try again later.