Follow
Daniel Timms
Daniel Timms
BiVACOR Inc
Verified email at bivacor.com - Homepage
Title
Cited by
Cited by
Year
A review of clinical ventricular assist devices
D Timms
Medical engineering & physics 33 (9), 1041-1047, 2011
1982011
A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices
D Timms, M Hayne, K McNeil, A Galbraith
Artificial organs 29 (7), 564-572, 2005
1842005
A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices
D Timms, M Hayne, K McNeil, A Galbraith
Artificial organs 29 (7), 564-572, 2005
1842005
A compact mock circulation loop for the in vitro testing of cardiovascular devices
DL Timms, SD Gregory, NA Greatrex, MJ Pearcy, JF Fraser, U Steinseifer
Artificial organs 35 (4), 384-391, 2011
1472011
Developments in control systems for rotary left ventricular assist devices for heart failure patients: a review
AHH AlOmari, AV Savkin, M Stevens, DG Mason, DL Timms, ...
Physiological measurement 34 (1), R1, 2012
1402012
Total artificial hearts: past, present, and future
WE Cohn, DL Timms, OH Frazier
Nature Reviews Cardiology 12 (10), 609-617, 2015
912015
Theoretical foundations of a Starling‐like controller for rotary blood pumps
RF Salamonsen, E Lim, N Gaddum, AHH AlOmari, SD Gregory, ...
Artificial organs 36 (9), 787-796, 2012
902012
Replication of the Frank-Starling response in a mock circulation loop
SD Gregory, M Stevens, D Timms, M Pearcy
2011 Annual International Conference of the IEEE Engineering in Medicine and …, 2011
822011
The BiVACOR rotary biventricular assist device: concept and in vitro investigation
D Timms, J Fraser, M Hayne, J Dunning, K McNeil, M Pearcy
Artificial organs 32 (10), 816-819, 2008
812008
Axial magnetic bearing development for the BiVACOR rotary BiVAD/TAH
NA Greatrex, DL Timms, N Kurita, EW Palmer, T Masuzawa
IEEE Transactions on Biomedical Engineering 57 (3), 714-721, 2009
802009
Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch
M Laumen, T Kaufmann, D Timms, P Schlanstein, S Jansen, S Gregory, ...
Artificial Organs 34 (10), 798-806, 2010
772010
Biventricular assist devices: a technical review
SD Gregory, D Timms, N Gaddum, DG Mason, JF Fraser
Annals of biomedical engineering 39, 2313-2328, 2011
732011
Heart pump controller
T Masuzawa, E Sasaki, D Timms
US Patent 8,632,449, 2014
672014
Starling‐like flow control of a left ventricular assist device: in vitro validation
NR Gaddum, M Stevens, E Lim, J Fraser, N Lovell, D Mason, D Timms, ...
Artificial organs 38 (3), E46-E56, 2014
642014
A hybrid mock circulation loop for a total artificial heart
F Nestler, AP Bradley, SJ Wilson, DL Timms, OH Frazier, WE Cohn
Artificial organs 38 (9), 775-782, 2014
482014
Exercise studies in patients with rotary blood pumps: cause, effects, and implications for Starling‐like control of changes in pump flow
RF Salamonsen, V Pellegrino, JF Fraser, K Hayes, D Timms, NH Lovell, ...
Artificial organs 37 (8), 695-703, 2013
482013
Physiological control of dual rotary pumps as a biventricular assist device using a master/slave approach
MC Stevens, S Wilson, A Bradley, J Fraser, D Timms
Artificial Organs 38 (9), 766-774, 2014
472014
Flow distribution during cardiopulmonary bypass in dependency on the outflow cannula positioning
TAS Kaufmann, M Hormes, M Laumen, DL Timms, T Schmitz‐Rode, ...
Artificial Organs 33 (11), 988-992, 2009
452009
The impact of aortic/subclavian outflow cannulation for cardiopulmonary bypass and cardiac support: a computational fluid dynamics study
TAS Kaufmann, M Hormes, M Laumen, DL Timms, T Linde, ...
Artificial organs 33 (9), 727-732, 2009
452009
Evaluation of left ventricular assist device performance and hydraulic force in a complete mock circulation loop
D Timms, M Hayne, A Tan, M Pearcy
Artificial organs 29 (7), 573-580, 2005
432005
The system can't perform the operation now. Try again later.
Articles 1–20