Follow
Carlos Quental
Carlos Quental
IDMEC, Instituto Superior Técnico, Universidade de Lisboa
Verified email at tecnico.ulisboa.pt
Title
Cited by
Cited by
Year
A multibody biomechanical model of the upper limb including the shoulder girdle
C Quental, J Folgado, J Ambrósio, J Monteiro
Multibody System Dynamics 28, 83-108, 2012
962012
Critical analysis of musculoskeletal modelling complexity in multibody biomechanical models of the upper limb
C Quental, J Folgado, J Ambrósio, J Monteiro
Computer methods in biomechanics and biomedical engineering 18 (7), 749-759, 2015
492015
Multibody biomechanical models of the upper limb
J Ambrósio, C Quental, B Pilarczyk, J Folgado, J Monteiro
Procedia IUTAM 2, 4-17, 2011
482011
Bone remodelling analysis of the humerus after a shoulder arthroplasty
C Quental, J Folgado, PR Fernandes, J Monteiro
Medical engineering & physics 34 (8), 1132-1138, 2012
402012
Bone adaptation impact of stemless shoulder implants: a computational analysis
M Comenda, C Quental, J Folgado, M Sarmento, J Monteiro
Journal of Shoulder and Elbow Surgery 28 (10), 1886-1896, 2019
392019
A new shoulder model with a biologically inspired glenohumeral joint
C Quental, J Folgado, J Ambrósio, J Monteiro
Medical engineering & physics 38 (9), 969-977, 2016
332016
A window moving inverse dynamics optimization for biomechanics of motion
C Quental, J Folgado, J Ambrósio
Multibody System Dynamics 38 (2), 157-171, 2016
282016
Stress analysis in a bone fracture fixed with topology-optimised plates
AA Al-Tamimi, C Quental, J Folgado, C Peach, P Bartolo
Biomechanics and modeling in mechanobiology 19, 693-699, 2020
272020
Full-thickness tears of the supraspinatus tendon: A three-dimensional finite element analysis
C Quental, J Folgado, J Monteiro, M Sarmento
Journal of biomechanics 49 (16), 3962-3970, 2016
262016
Bone remodelling of the scapula after a total shoulder arthroplasty
C Quental, PR Fernandes, J Monteiro, J Folgado
Biomechanics and modeling in mechanobiology 13, 827-838, 2014
252014
Multibody system of the upper limb including a reverse shoulder prosthesis
C Quental, J Folgado, J Ambrósio, J Monteiro
Journal of Biomechanical Engineering 135 (11), 111005, 2013
232013
Influence of the musculotendon dynamics on the muscle force-sharing problem of the shoulder—a fully inverse dynamics approach
Q Carlos, A Margarida, A Jorge, G SB, F João
Journal of biomechanical engineering 140 (7), 071005, 2018
212018
Computational design and fabrication of a novel bioresorbable cage for tibial tuberosity advancement application
M Castilho, J Rodrigues, E Vorndran, U Gbureck, C Quental, J Folgado, ...
Journal of the mechanical behavior of biomedical materials 65, 344-355, 2017
202017
Computational analysis of polyethylene wear in anatomical and reverse shoulder prostheses
C Quental, J Folgado, PR Fernandes, J Monteiro
Medical & biological engineering & computing 53, 111-122, 2015
202015
Primary stability analysis of stemless shoulder implants
C Quental, J Folgado, M Comenda, J Monteiro, M Sarmento
Medical Engineering & Physics 81, 22-29, 2020
192020
Subject-specific bone remodelling of the scapula
C Quental, J Folgado, PR Fernandes, J Monteiro
Computer methods in biomechanics and biomedical engineering 17 (10), 1129-1143, 2014
182014
Bone remodelling of the humerus after a resurfacing and a stemless shoulder arthroplasty
B Santos, C Quental, J Folgado, M Sarmento, J Monteiro
Clinical Biomechanics 59, 78-84, 2018
172018
Influence of the PFNA screw position on the risk of cut-out in an unstable intertrochanteric fracture: a computational analysis
C Quental, S Vasconcelos, J Folgado, F Guerra-Pinto
Medical Engineering & Physics 97, 70-76, 2021
112021
Proximal and mid-thigh fascia lata graft constructs used for arthroscopic superior capsule reconstruction show equivalent biomechanical properties: an in vitro human cadaver study
CI de Campos Azevedo, ACLPG Ângelo, C Quental, S Gonçalves, ...
JSES international 5 (3), 439-446, 2021
92021
Computational reverse shoulder prosthesis model: Experimental data and verification
A Martins, C Quental, J Folgado, J Ambrósio, J Monteiro, M Sarmento
Journal of biomechanics 48 (12), 3242-3251, 2015
82015
The system can't perform the operation now. Try again later.
Articles 1–20