Follow
Po-Lin Hsu
Po-Lin Hsu
Unknown affiliation
No verified email
Title
Cited by
Cited by
Year
Axial-flow blood pump
PL Hsu, U Steinseifer, J Parker, R Autschbach
US Patent 9,370,613, 2016
1082016
Mechanical circulatory support for right heart failure: current technology and future outlook
PL Hsu, J Parker, C Egger, R Autschbach, T Schmitz‐Rode, U Steinseifer
Artificial organs 36 (4), 332-347, 2012
622012
On the representation of effective stress for computing hemolysis
P Wu, Q Gao, PL Hsu
Biomechanics and modeling in mechanobiology 18, 665-679, 2019
352019
Atrial versus ventricular cannulation for a rotary ventricular assist device
D Timms, S Gregory, PL Hsu, B Thomson, M Pearcy, K McNeil, J Fraser, ...
Artificial organs 34 (9), 714-720, 2010
302010
Mock circulatory loops used for testing cardiac assist devices: A review of computational and experimental models
F Cappon, T Wu, T Papaioannou, X Du, PL Hsu, AW Khir
The International Journal of Artificial Organs 44 (11), 793-806, 2021
272021
An energy-dissipation-based power-law formulation for estimating hemolysis
P Wu, S Groß-Hardt, F Boehning, PL Hsu
Biomechanics and modeling in mechanobiology 19, 591-602, 2020
242020
Evaluation of hydraulic radial forces on the impeller by the volute in a centrifugal rotary blood pump
F Boehning, DL Timms, F Amaral, L Oliveira, R Graefe, PL Hsu, ...
Artificial Organs 35 (8), 818-825, 2011
202011
On the accuracy of hemolysis models in Couette‐type blood shearing devices
P Wu, F Boehning, S Groß‐Hardt, PL Hsu
Artificial organs 42 (10), E290-E303, 2018
172018
Review of recent patents on foldable ventricular assist devices
PL Hsu, M McIntyre, M Kuetting, J Parker, C Egger, R Autschbach, ...
Recent Patents on Biomedical Engineering (Discontinued) 5 (3), 208-222, 2012
162012
A numerical simulation comparing a cavopulmonary assist device and VA ECMO for failing Fontan support
PL Hsu, D Wang, C Ballard-Croft, D Xiao, JB Zwischenberger
ASAIO Journal 63 (5), 604-612, 2017
132017
In vitro study of an intra-aortic VAD: Effect of reverse-rotating mode on ventricular recovery
Y Wang, PL Hsu, HC Love, DL Timms, RA McMahon
2015 37th Annual International Conference of the IEEE Engineering in …, 2015
112015
Hybrid extracorporeal membrane oxygenation using avalon elite double lumen cannula ensures adequate heart/brain oxygen supply
J Zhao, D Wang, C Ballard-Croft, J Wang, PL Hsu, M Bacchetta, ...
The Annals of Thoracic Surgery 104 (3), 847-853, 2017
102017
Hydraulic and hemodynamic performance of a minimally invasive intra-arterial right ventricular assist device
PL Hsu, R Graefe, F Boehning, C Wu, J Parker, R Autschbach, ...
The International journal of artificial organs 37 (9), 697-705, 2014
102014
Systematic Design of a Magnetically Levitated Brushless DC Motor for a Reversible Rotary Intra‐Aortic Blood Pump
Y Wang, TG Logan, PA Smith, PL Hsu, WE Cohn, L Xu, RA McMahon
Artificial Organs 41 (10), 923-933, 2017
92017
In vitro evaluation of the dual‐diffuser design for a reversible rotary intra‐aortic ventricular assist device
Y Wang, PA Smith, DL Timms, PL Hsu, RA McMahon
Artificial Organs 40 (9), 884-893, 2016
92016
In‐Series Versus In‐Parallel Mechanical Circulatory Support for the Right Heart: A Simulation Study
PL Hsu, M McIntyre, F Boehning, W Dang, J Parker, R Autschbach, ...
Artificial Organs 40 (6), 561-567, 2016
82016
Design method of a foldable ventricular assist device for minimally invasive implantation
PL Hsu, Y Wang, F Amaral, J Parker, T Schmitz‐Rode, R Autschbach, ...
Artificial Organs 38 (4), 298-308, 2014
82014
Dielectrophoresis-based method for measuring the multiangle mechanical properties of biological cells
B Zhu, W Li, M Zhu, PL Hsu, L Sun, H Yang
BioMed Research International 2020, 2020
72020
An extended computational model of the circulatory system for designing ventricular assist devices
PL Hsu, SJ Cheng, RC Saumarez, WN Dawes, RA McMahon
ASAIO Journal 54 (6), 594-599, 2008
72008
A mock heart engineered with helical aramid fibers for in vitro cardiovascular device testing
SH Jansen-Park, PL Hsu, I Müller, U Steinseifer, D Abel, R Autschbach, ...
Biomedical Engineering/Biomedizinische Technik 62 (2), 139-148, 2017
62017
The system can't perform the operation now. Try again later.
Articles 1–20